Ultrasound-guided needle-scalpel release of the flexor retinaculum at the carpal tunnel: a cadaveric pilot observation
Ondřej Naňka1orcid, Kamal Mezian2orcid, Tomas Novotny3,4orcid, Levent Özçakar5orcid, Wei-Ting Wu6,7orcid, Ke-Vin Chang6,7,8orcid
Journal of Yeungnam Medical Science 2026;43:71.
DOI: https://doi.org/10.12701/jyms.2026.43.71
Published online: October 15, 2026

1Institute of Anatomy, First Faculty of Medicine, Charles University, Prague, Czech Republic

2Department of Rehabilitation Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic

3Department of Orthopaedics, Faculty of Health Studies, Jan Evangelista Purkyně University in Ústí nad Labem and Masaryk Hospital, Ústí nad Labem, Czech Republic

4Department of Orthopaedic Surgery, Faculty of Medicine in Hradec Králové, Charles University, Hradec Králové, Czech Republic

5Department of Physical and Rehabilitation Medicine, Hacettepe University Medical School, Ankara, Türkiye

6Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, Taipei, Taiwan

7Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei, Taiwan

8Center for Regional Anesthesia and Pain Medicine, Taipei Municipal Wangfang Hospital, Taipei Medical University, Taipei, Taiwan

Corresponding author: Wei-Ting Wu, MD Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, No. 87, Nei-Jiang Rd., Wan-Hwa District, Taipei 108, Taiwan Tel: +886-2-2371-7101 ext. 215318 E-mail: wwtaustin@yahoo.com.tw
Ke-Vin Chang, MD, PhD Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch, No. 87, Nei-Jiang Rd., Wan-Hwa District, Taipei 108, Taiwan Tel: +886-2-2371-7101 ext. 216531 E-mail: kvchang011@gmail.com
• Received: September 23, 2026   • Revised: October 7, 2026   • Accepted: October 12, 2026

© 2026 Yeungnam University College of Medicine, Yeungnam University Institute of Medical Science

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 720 Views
  • 89 Download
A needle-scalpel is a minimally invasive instrument that combines the puncturing function of a needle with a small cutting edge to release or dissect pathological soft tissues in musculoskeletal disorders. We report a pilot cadaveric investigation evaluating the feasibility of ultrasound-guided needle-scalpel release of the flexor retinaculum at the wrist compared to conventional needle release. Four cadaveric wrists were included: two underwent release using a needle-scalpel, and the remaining two underwent the same procedure using a 20-gauge needle for comparison. All procedures were guided by using a Samsung HS30 ultrasound system (Samsung Medison Co., Ltd., Seoul, Korea) with a high-frequency linear transducer (LN5-12). All wrists were obtained from cadavers preserved using the Fix for Life embalming method [1], a soft-fixation technique designed to maintain tissue flexibility and preserve anatomical characteristics suitable for ultrasound-guided procedures and subsequent dissections.
For the needle-scalpel procedure, the ultrasound transducer was initially placed in the short-axis plane between the scaphoid and pisiform [2]. The needle-scalpel was inserted using an out-of-plane approach immediately ulnar to the median nerve (Fig. 1) within the transverse safe zone, defined as the space between the ulnar border of the median nerve and the radial border of the ulnar vessels or the hook of the hamate. After confirming entry into the carpal tunnel, the transducer was rotated to obtain a long-axis view, allowing visualization of the flexor retinaculum and needle-scalpel trajectory (Fig. 1). The needle-scalpel was advanced and withdrawn longitudinally for 100 repetitions to release the flexor retinaculum (Supplementary Video 1). Ultrasound was used throughout the procedure to verify the trajectory and positioning with respect to the surrounding structures [3]. The needle-scalpel was maintained superficial to the flexor digitorum superficialis tendons to minimize the risk of injury to the median nerve and other structures within the carpal tunnel. The same ultrasound-guided procedure was performed on the other two wrists using a 20-gauge needle with 100 longitudinal advancement-and-withdrawal movements against the flexor retinaculum (Fig. 2, Supplementary Video 2). In the present cadaveric study, 100 repetitions were standardized for both the needle-scalpel and conventional needle techniques to minimize the possibility of incomplete release resulting from insufficient repetitions and to ensure comparable experimental conditions between the two techniques.
Subsequent anatomical dissection was performed to evaluate the extent of the release. Among the two wrists treated with the needle-scalpel, partial disruption of the flexor retinaculum was observed in only one specimen, predominantly at the distal edge (Fig. 1). No substantial release was observed for the other specimen. After complete surgical division and reflection of the flexor retinaculum, examination of its undersurface revealed only multiple puncture marks. Neither wrist treated with the 20-gauge needle showed appreciable disruption of the flexor retinaculum, with only multiple puncture marks identified on the undersurface (Fig. 2).
These preliminary findings indicate that complete percutaneous division of the flexor retinaculum may be difficult using a needle-scalpel with repetitive longitudinal movements alone. Although a needle-scalpel may produce greater disruption than a conventional needle [4,5], its cutting surface may be insufficient to achieve reliable complete transection of the flexor retinaculum, as illustrated by its thickness in the cross-sectional view of another cadaveric wrist (Supplementary Fig. 1). This assumption was further validated by direct examination after the flexor retinaculum was incised/reflected. Dissection using a needle-scalpel was attempted but proved difficult because of the toughness of the retinaculum (Supplementary Video 3). A device with a larger cutting blade or modification of the cutting technique and trajectory may be necessary to achieve an effective and reproducible release. Further cadaveric studies are warranted to optimize the device and procedural technique while evaluating the safety of adjacent neurovascular and tendinous structures.
Supplementary Videos 1–3 and Supplementary Fig. 1 can be found via https://doi.org/10.12701/jyms.2026.43.71.
Supplementary Video 1.
Supplementary Video 2.
Supplementary Video 3.
Supplementary Figure 1.
jyms-2026-43-71-Supplementary-Fig-1.pdf

Ethics statement

Not applicable. Cadaveric procedures were conducted with approval from the Anatomical Donation Department, Charles University, Prague, Czech Republic.

Conflicts of interest

Ke-Vin Chang and Wei-Ting Wu have been editorial board members of Journal of Yeungnam Medical Science since 2021. They were not involved in the review process of this manuscript. There are no other conflicts of interest to declare.

Funding

This study was funded by the National Taiwan University Hospital Bei-Hu Branch, Ministry of Science and Technology, Taiwan (MOST 106-2314-B-002-180-MY3 and MOST 109-2314-B-002-114-MY3), and National Science and Technology Council, Taiwan (NSTC 112-2314-B-002-134, NSTC 113-2314-B-002-208-MY2 and NSTC 113-2314-B-002-209-MY2).

Author contributions

Conceptualization: ON, KM, LÖ, WTW, KVC; Data curation: TN, WTW, KVC; Formal analysis: ON, KVC; Funding acquisition: WTW, KVC; Investigation, Methodology: ON, KM, TN, WTW, KVC; Project administration, Software: ON, WTW, KVC; Resources, Visualization: ON, KM, WTW, KVC; Supervision: ON, TN, LÖ, KVC; Validation: all authors; Writing-original draft: ON, LÖ, WTW, KVC; Writing-review & editing: all authors.

Use of artificial intelligence

ChatGPT (OpenAI) was used to assist in the preparation of figures. The authors reviewed and verified the final figures and take full responsibility for their accuracy and content.

Fig. 1.
Ultrasound-guided needle-scalpel release of the flexor retinaculum (FR). (A) Short-axis view showing out-of-plane needle-scalpel insertion ulnar to the median nerve (MN). (B) Long-axis view showing the needle-scalpel trajectory along the FR. (C) Anatomical dissection demonstrating partial disruption of the FR, predominantly at its distal edge. The white arrows indicate the needle-scalpel, and the white arrowhead indicates partial disruption of the FR. FCR, flexor carpi radialis; R, radius; T, triquetrum; FDS, flexor digitorum superficialis; FDP, flexor digitorum profundus; FPL, flexor pollicis longus.
jyms-2026-43-71f1.jpg
Fig. 2.
Ultrasound-guided needle release of the flexor retinaculum (FR). (A) Short-axis view showing out-of-plane needle insertion ulnar to the median nerve (MN). (B) Long-axis view showing the needle trajectory along the FR. (C) Anatomical dissection showing no appreciable disruption of the FR. The white arrows indicate the needle. FCR, flexor carpi radialis; R, radius; T, triquetrum; FDS, flexor digitorum superficialis; FDP, flexor digitorum profundus.
jyms-2026-43-71f2.jpg
  • 1. Naňka O, Mezian K, Chang KV, Wu WT, Ricci V, Özçakar L. Cadaveric analyses of injectate distribution patterns in ultrasound-guided rotator interval, dual-target, and posterior glenohumeral injections. Insights Imaging 2026;17:77.ArticlePubMedPMC
  • 2. Wu WT, Chang KV, Tsai YY, Chi SY, Mezian K, Ricci V, et al. USMSIT/NMUSIT fundamental guide on diagnostic and interventional wrist/hand ultrasonography. J Med Ultrasound 2026;34:131–9.ArticlePubMedPMC
  • 3. Wu WT, Chang KV, Hsu YC, Tsai YY, Mezian K, Ricci V, et al. Ultrasound imaging and guidance for distal peripheral nerve pathologies at the wrist/hand. Diagnostics (Basel) 2023;13:1928.ArticlePubMedPMC
  • 4. Chen CC, Wu WT, Chang KV, Huang SW, Özçakar L. Ultrasound-guided retinaculum release with a needle scalpel for de Quervain’s disease: a cadaveric pilot observation. Med Ultrason 2026;28:122–3.ArticlePubMedPDF
  • 5. Ji G, Chen W. Clinical application of ultrasound-guided acupotomy combined with platelet-rich plasma in the treatment of carpal tunnel syndrome. Front Surg 2025;12:1629781.ArticlePubMedPMC

Figure & Data

References

    Citations

    Citations to this article as recorded by  

      Figure
      • 0
      • 1
      Ultrasound-guided needle-scalpel release of the flexor retinaculum at the carpal tunnel: a cadaveric pilot observation
      Image Image
      Fig. 1. Ultrasound-guided needle-scalpel release of the flexor retinaculum (FR). (A) Short-axis view showing out-of-plane needle-scalpel insertion ulnar to the median nerve (MN). (B) Long-axis view showing the needle-scalpel trajectory along the FR. (C) Anatomical dissection demonstrating partial disruption of the FR, predominantly at its distal edge. The white arrows indicate the needle-scalpel, and the white arrowhead indicates partial disruption of the FR. FCR, flexor carpi radialis; R, radius; T, triquetrum; FDS, flexor digitorum superficialis; FDP, flexor digitorum profundus; FPL, flexor pollicis longus.
      Fig. 2. Ultrasound-guided needle release of the flexor retinaculum (FR). (A) Short-axis view showing out-of-plane needle insertion ulnar to the median nerve (MN). (B) Long-axis view showing the needle trajectory along the FR. (C) Anatomical dissection showing no appreciable disruption of the FR. The white arrows indicate the needle. FCR, flexor carpi radialis; R, radius; T, triquetrum; FDS, flexor digitorum superficialis; FDP, flexor digitorum profundus.
      Ultrasound-guided needle-scalpel release of the flexor retinaculum at the carpal tunnel: a cadaveric pilot observation

      JYMS : Journal of Yeungnam Medical Science
      TOP