Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure.
Jong Su Paek, Jae Chul Song, Hee Kyung Lee
Department of Dentistry College of Medicine, Yeungnam University, Daegu, Korea.
Abstract
BACKGROUND: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. MATERIALS AND METHODS: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. RESULTS: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurement. The distance between RGo and LGo showed the largest difference (2.23 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). CONCLUSION: It is concluded that closeness of repeated measurements to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.
Key Words: 3-dimensional computerized tomography, 3-dimensional cephalogram, Accuracy, Mean difference
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 617 View
  • 1 Download
Related articles in Yeungnam Univ J Med


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
170 Hyeonchung-ro, Nam-gu, Daegu 42415, Korea
Tel: +82-53-640-6832    Fax: +82-53-651-0394    E-mail: jyms@yu.ac.kr                

Copyright © 2022 by Yeungnam University College of Medicine, Yeungnam University Institute Medical Science.

Developed in M2PI

Close layer
prev next