1. Tosini G. Locomotor activity in rodents. Methods Mol Biol 2007;362:95–101.
2. Gray VC, Hughes RN. Drug-, dose- and sex-dependent effects of chronic fluoxetine, reboxetine and venlafaxine on openfield behavior and spatial memory in rats. Behav Brain Res 2015;281:43–54.
4. Machado DG, Cunha MP, Neis VB, Balen GO, Colla A, Grando J, et al. Fluoxetine reverses depressive-like behaviors and increases hippocampal acetylcholinesterase activity induced by olfactory bulbectomy. Pharmacol Biochem Behav 2012;103:220–9.
8. Machado DG, Bettio LE, Cunha MP, Capra JC, Dalmarco JB, Pizzolatti MG, et al. Antidepressant-like effect of the extract of Rosmarinus officinalis in mice: involvement of the monoaminergic system. Prog Neuropsychopharmacol Biol Psychiatry 2009;33:642–50.
11. Otero L, Zurita M, Aguayo C, Bonilla C, Rodríguez A, Vaquero J. Video-tracking-box linked to smart software as a tool for evaluation of locomotor activity and orientation in brain-injured rats. J Neurosci Methods 2010;188:53–7.
12. Kulikov AV, Tikhonova MA, Kulikov VA. Automated measurement of spatial preference in the open field test with transmitted lighting. J Neurosci Methods 2008;170:345–51.
13. Guzmán-Valdivia CH, Blanco-Ortega A, Oliver-Salazar MA, Carrera-Escobedo JL. Therapeutic motion analysis of lower limbs using Kinovea. Int J Soft Comput Eng 2013;3:359–65.
14. Balsalobre-Fernández C, Tejero-González CM, del Campo-Vecino J, Bavaresco N. The concurrent validity and reliability of a low-cost, high-speed camera-based method for measuring the flight time of vertical jumps. J Strength Cond Res 2014;28:528–33.
16. Moral-Muñoz JA, Esteban-Moreno B, Arroyo-Morales M, Cobo MJ, Herrera-Viedma E. agreement between face-to-face and free software video analysis for assessing hamstring flexibility in adolescents. J Strength Cond Res 2015;29:2661–5.
17. Padulo J, Vando S, Chamari K, Chaouachi A, Bagno D, Pizzolato F. Validity of the MarkWiiR for kinematic analysis during walking and running gaits. Biol Sport 2015;32:53–8.
18. Elwardany SH, El-Sayed WH, Ali MF. Reliability of Kinovea computer program in measuring cervical range of motion in sagittal plane. Open Access Libr J 2015;2:e1916.
19. Abd Elrahim RM, Embaby EM, Ali MF, Kamel RM. Interrater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion. Bull Fac Phys Ther 2016;21:80–7.
20. Grigg J, Haakonssen E, Rathbone E, Orr R, Keogh JWL. The validity and intra-tester reliability of markerless motion capture to analyse kinematics of the BMX supercross gate start. Sports Biomech 2017;1–19.
21. Fleiss JL. The design and analysis of clinical experiments. New York: Wiley; 1986.
23. Mukaka MM. Statistics corner: a guide to appropriate use of correlation coefficient in medical research. Malawi Med J 2012;24:69–71.
24. Tzschentke TM. Measuring reward with the conditioned place preference (CPP) paradigm: update of the last decade. Addict Biol 2007;12:227–462.