- Correlation between Microalbuminuria Checked by RIA & Micral-Test®.
-
Chan Woo Lee, Kyu Chang Won, Soo Bong Choi
-
Yeungnam Univ J Med. 1991;8(2):158-163. Published online December 31, 1991
-
DOI: https://doi.org/10.12701/yujm.1991.8.2.158
-
-
Abstract
PDF
- It is evident that an elevation of airway albumin excreation rate without clinical proteinuria strongly predicts a later progression on diabetic renal disease. So we studied the correlation between Microalbumin checkly RIA & Micral-Test®. We collected urine between 08:00 h and 08:00 h next day and then checked microalbuminuria by radioimmunoassay method and Micral-Test® The results are as follows: 1. There was significant correlation between microalbuminuria checked by RIA & Micral-Test® 2. There was poor correlation between diabetes duration or HV-A1c and maximal change in albumin excreation rate. 3. So we concluded that Micral-Test® can be used in laboratory instead of RIA.