Skip Navigation
Skip to contents

JYMS : Journal of Yeungnam Medical Science

Indexed in: ESCI, Scopus, PubMed,
PubMed Central, CAS, DOAJ, KCI
FREE article processing charge
OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
2 "Robotics"
Filter
Filter
Article category
Keywords
Publication year
Authors
Funded articles
Case report
DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report
Young Hwii Ko, Jong Gyun Ha, Jae Yoon Jang, Yeung Uk Kim
J Yeungnam Med Sci. 2024;41(1):48-52.   Published online January 4, 2024
DOI: https://doi.org/10.12701/jyms.2023.01032
  • 532 View
  • 33 Download
AbstractAbstract PDF
While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.
Original article
User perception of medical service robots in hospital wards: a cross-sectional study
Jung Hwan Lee, Jae Meen Lee, Jaehyun Hwang, Joo Young Park, Mijeong Kim, Dong Hwan Kim, Jae Il Lee, Kyoung Hyup Nam, In Ho Han
J Yeungnam Med Sci. 2022;39(2):116-123.   Published online October 5, 2021
DOI: https://doi.org/10.12701/yujm.2021.01319
  • 4,271 View
  • 100 Download
  • 2 Web of Science
  • 3 Crossref
AbstractAbstract PDF
Background
Recently, there have been various developments in medical service robots (MSRs). However, few studies have examined the perceptions of those who use it. The purpose of this study is to identify user perceptions of MSRs.
Methods
We conducted a survey of 320 patients, doctors, and nurses. The contents of the survey were organized as follows: external appearances, perceptions, expected utilization, possible safety accidents, and awareness of their responsibilities. Statistical analyses were performed using t-test, chi-square test, and analysis of variance.
Results
The most preferred appearance was the animal type, with a screen. The overall average score of positive questions was 3.64±0.98 of 5 points and that of negative questions was 3.24±0.99. Thus, the results revealed that the participants had positive perceptions of MSR. The overall average of all expected utilization was 4.05±0.84. The most expected utilization was to guide hospital facilities. The most worrisome accident was exposure to personal information. Moreover, participants thought that the overall responsibility of the robot user (hospital) was greater than that of the robot manufacturer in the case of safety accidents.
Conclusion
The perceptions of MSRs used in hospital wards were positive, and the overall expected utilization was high. It is necessary to recognize safety accidents for such robots, and sufficient attention is required when developing and manufacturing robots.

Citations

Citations to this article as recorded by  
  • Robotic Anesthesia: A Vision for 2050
    Thomas M. Hemmerling, Sean D. Jeffries
    Anesthesia & Analgesia.2024; 138(2): 239.     CrossRef
  • Exploring the influence of anthropomorphic appearance on usage intention on online medical service robots (OMSRs): A neurophysiological study
    Yi Ding, Ran Guo, Muhammad Bilal, Vincent G. Duffy
    Heliyon.2024; 10(5): e26582.     CrossRef
  • Customer acceptance of service robots under different service settings
    Yi Li, Chongli Wang, Bo Song
    Journal of Service Theory and Practice.2023; 33(1): 46.     CrossRef

JYMS : Journal of Yeungnam Medical Science